JoistLedgerSpans, joists and footings straight from the code tables.

Decking for a 14 × 12 ft deck in composite, diagonal layout

5½″ composite boards
35× 12 ft
30 rows across 14 ft — 414 linear ft including 15% waste
Plan — boards across the joists14 ft12 ft30rows5.75″ repeatactual width + gap35 boards · 420 screws
Boards to buy35× 12 ft
Linear feet360 ft plus 15% waste414ft
Rows of decking14 ft ÷ 5.75″ repeat30rows
Board repeat5.5″ actual width + 0.25″ gap — not the nominal size5.75in
Deck area14 × 12 ft168ft²
Joists crossedat 24″ o.c. over 12 ft7joists
Deck screwstwo per board-joist crossing — about 2 boxes of 350420screws
Layoutat 45°, every board is cut at both endsdiagonal
Butt joints12 ft boards cover the 12 ft run in one pieceNone needed
Deck width
14 ft
Deck length
12 ft
Board
composite
Layout
diagonal
Joist spacing
24 in o.c.

Nominal width is not actual width

This is where board counts go wrong. A composite board measures its real width, and with the gap it needs the repeat is 5.75″ — which is what actually decides the row count.

14 ft of deck at that repeat is 30 rows, and 35 boards once 15% waste for the diagonal layout is added.

Working from the nominal size undercounts by close to a tenth.

The gap is not optional in either direction

Treated lumber is sold wet and shrinks. Composite expands with heat. Gap too tight on composite and it buckles in July; gap too wide on wet treated lumber and by autumn you have gaps that swallow a phone.

Screws

420 — two at every board-joist crossing, across 7 joists. One screw per crossing lets the board cup and lift at the corner, and that is the single most common reason a deck looks tired after two summers.

Read the end grain

Lay boards bark-side up. A board cups away from its bark side, so bark-up sheds water off the crown rather than holding it in a trough.

Butt joints

Where the run exceeds a standard board length, stagger the joints so no two adjacent rows meet over the same joist — and double the joist under every joint. A butt joint on a single joist gives each board about ¾ inch of bearing, which is not enough for either board.

Notes

  • **Nominal width is not actual width.** A "5½″ composite" board measures 5.5″ across. With a 0.25″ gap the repeat is 5.75″, which is what decides the row count — 30 rows here. Working from the nominal size undercounts by close to a tenth.
  • Expands with heat rather than shrinking — gap per the manufacturer, usually ¼″. The gap is not optional in either direction: too tight on composite and it buckles in July; too wide on wet treated lumber and you get gaps you can drop a phone through by autumn.
  • Diagonal layout, 15% waste — at 45°, every board is cut at both ends. Order the full allowance in one go; diagonal offcuts rarely fit anywhere else on the deck.
  • A 12 ft board covers the 12 ft run in one piece. Worth paying for: an unbroken board is stronger, drains better and looks like a deck rather than a repair.
  • Fasten with two screws at every board-joist crossing — 420 screws here. One screw lets the board cup and lift at the corner, and it is the single most common reason a deck looks tired after two summers.
  • Lay the boards bark-side up if you can read the end grain. A board cups away from the bark side, so bark-up sheds water off the crown instead of holding it in a trough.

Nearby sizes

Read more