JoistLedgerSpans, joists and footings straight from the code tables.

Framing Quantities

Joists, blocking, hangers and fasteners for a deck of a given size.

A deck frame is four decisions, each of which has a published table behind it: how far the joists span, how far the beam spans between posts, how big the posts are, and how the whole thing attaches to the house.

Joists

IRC table R507.6 gives allowable joist spans by species, size and spacing. Southern pine 2×8 at 16 in on center spans 13 ft 1 in; the same joist at 24 in on center spans 10 ft 10 in. Hem-fir is shorter than both.

Two things shrink those numbers and are missed constantly:

  • A cantilever counts. The IRC allows a joist to overhang up to one quarter of its actual back span, and the back span is what the table governs.
  • Ledger-hung joists carry a different load path than joists bearing on a beam at both ends, and a deck with hot tub, planters, or a roof over it is outside the residential table entirely.

Beams

R507.5 gives beam spans as a function of the joist span they carry, not of the deck's length. A triple 2×10 southern pine beam carrying 12 ft of joist spans 8 ft 6 in between posts. Carrying 8 ft of joist, the same beam spans 10 ft 5 in.

Which means the way to shorten a beam span is to move the posts, and the way to lengthen it is to shorten the joists — a swap most plans discover late.

Posts

4×4 is permitted up to 8 ft of unbraced height in the current IRC, 6×6 above that, and 6×6 is what most jurisdictions want regardless once a deck is more than a step off the ground. The post-to-beam connection is a rated bracket, not toenails, and the post sits on the footing hardware rather than in the ground.

The ledger is the part that kills people

Deck collapses are almost always ledger failures, and almost always at a ledger that was nailed rather than bolted, or bolted through nothing but the rim joist's sheathing.

R507.9 specifies 1/2 in lag screws or through-bolts in a staggered pattern, with spacing set by the joist span, and flashing above the ledger so water cannot sit behind it. No fastener spec saves a ledger attached over siding, over brick veneer, or to a cantilevered floor.

What to check first

Whether the deck can be freestanding. A frame on its own posts avoids the ledger question entirely, costs two more footings, and is the answer more often than it is offered.