Decking for a 18 × 14 ft deck in 2 × 6 treated, straight layout
| Boards to buy | 41× 16 ft |
|---|---|
| Linear feet546 ft plus 5% waste | 573ft |
| Rows of decking18 ft ÷ 5.625″ repeat | 39rows |
| Board repeat5.5″ actual width + 0.125″ gap — not the nominal size | 5.625in |
| Deck area18 × 14 ft | 252ft² |
| Joists crossedat 24″ o.c. over 14 ft | 8joists |
| Deck screwstwo per board-joist crossing — about 2 boxes of 350 | 624screws |
| Layoutboards run perpendicular to the joists — least waste | straight |
| Butt joints16 ft boards cover the 14 ft run in one piece | None needed |
- Deck width
- 18 ft
- Deck length
- 14 ft
- Board
- 2 × 6 treated
- Layout
- straight
- Joist spacing
- 24 in o.c.
Nominal width is not actual width
This is where board counts go wrong. A 2 × 6 treated board measures its real width, and with the gap it needs the repeat is 5.625″ — which is what actually decides the row count.
18 ft of deck at that repeat is 39 rows, and 41 boards once 5% waste for the straight layout is added.
Working from the nominal size undercounts by close to a tenth.
The gap is not optional in either direction
Treated lumber is sold wet and shrinks. Composite expands with heat. Gap too tight on composite and it buckles in July; gap too wide on wet treated lumber and by autumn you have gaps that swallow a phone.
Screws
624 — two at every board-joist crossing, across 8 joists. One screw per crossing lets the board cup and lift at the corner, and that is the single most common reason a deck looks tired after two summers.
Read the end grain
Lay boards bark-side up. A board cups away from its bark side, so bark-up sheds water off the crown rather than holding it in a trough.
Butt joints
Where the run exceeds a standard board length, stagger the joints so no two adjacent rows meet over the same joist — and double the joist under every joint. A butt joint on a single joist gives each board about ¾ inch of bearing, which is not enough for either board.
Notes
- **Nominal width is not actual width.** A "2 ×" board measures 5.5″ across. With a 0.125″ gap the repeat is 5.625″, which is what decides the row count — 39 rows here. Working from the nominal size undercounts by close to a tenth.
- Thicker and stiffer; spans further between joists. The gap is not optional in either direction: too tight on composite and it buckles in July; too wide on wet treated lumber and you get gaps you can drop a phone through by autumn.
- Straight layout, 5% waste — boards run perpendicular to the joists — least waste. This is the least wasteful way to lay a deck, and the fastest.
- A 16 ft board covers the 14 ft run in one piece. Worth paying for: an unbroken board is stronger, drains better and looks like a deck rather than a repair.
- Fasten with two screws at every board-joist crossing — 624 screws here. One screw lets the board cup and lift at the corner, and it is the single most common reason a deck looks tired after two summers.
- Lay the boards bark-side up if you can read the end grain. A board cups away from the bark side, so bark-up sheds water off the crown instead of holding it in a trough.
Nearby sizes
- Decking for a 16 × 14 ft deck in 2 × 6 treated, straight layout
- Decking for a 20 × 14 ft deck in 2 × 6 treated, straight layout
- Decking for a 14 × 14 ft deck in 2 × 6 treated, straight layout
- Decking for a 22 × 14 ft deck in 2 × 6 treated, straight layout
- Decking for a 18 × 12 ft deck in 2 × 6 treated, straight layout
- Decking for a 18 × 16 ft deck in 2 × 6 treated, straight layout
- Decking for a 18 × 10 ft deck in 2 × 6 treated, straight layout
- Decking for a 18 × 18 ft deck in 2 × 6 treated, straight layout
- Decking for a 18 × 14 ft deck in 5/4 × 6 treated, straight layout
- Decking for a 18 × 14 ft deck in composite, straight layout
- Decking for a 18 × 14 ft deck in cedar, straight layout
- Decking for a 18 × 14 ft deck in 2 × 6 treated, diagonal layout
- Decking for a 18 × 14 ft deck in 2 × 6 treated, herringbone layout
- Decking for a 18 × 14 ft deck in 2 × 6 treated, straight layout
- Decking for a 18 × 14 ft deck in 2 × 6 treated, straight layout
Read more
- How Many Footings Does a Deck Need? Work Backwards From Tributary AreaNobody decides footing count directly. It falls out of how far the beam can span, and how much deck each post is holding up.
- Cost to Build a Deck per Square Foot: Where the Money Actually GoesDecking boards are the part everyone shops for and about a quarter of the bill. The framing underneath is where the price is decided.
- Ledger Attachment: The Detail That Causes Nearly Every Deck CollapseSpan tables get the attention. Ledger failure is what actually drops decks, and it is almost always one of four specific mistakes.
- Deck Joist Span Tables: The Four Assumptions That Have to HoldThe span table is not a rule about lumber. It is a rule about lumber carrying 40 psf, dry, at No. 2 grade, with no cantilever, and any of those can be false on your deck.