JoistLedgerSpans, joists and footings straight from the code tables.

Decking for a 22 × 20 ft deck in cedar, straight layout

5/4 × 6 cedar boards
50× 20 ft
47 rows across 22 ft — 987 linear ft including 5% waste
Plan — boards across the joists22 ft20 ft47rows5.688″ repeatactual width + gap50 boards · 1,974 screws
Boards to buy50× 20 ft
Linear feet940 ft plus 5% waste987ft
Rows of decking22 ft ÷ 5.688″ repeat47rows
Board repeat5.5″ actual width + 0.1875″ gap — not the nominal size5.688in
Deck area22 × 20 ft440ft²
Joists crossedat 12″ o.c. over 20 ft21joists
Deck screwstwo per board-joist crossing — about 6 boxes of 3501,974screws
Layoutboards run perpendicular to the joists — least wastestraight
Butt joints20 ft boards cover the 20 ft run in one pieceNone needed
Deck width
22 ft
Deck length
20 ft
Board
cedar
Layout
straight
Joist spacing
12 in o.c.

Nominal width is not actual width

This is where board counts go wrong. A cedar board measures its real width, and with the gap it needs the repeat is 5.688″ — which is what actually decides the row count.

22 ft of deck at that repeat is 47 rows, and 50 boards once 5% waste for the straight layout is added.

Working from the nominal size undercounts by close to a tenth.

The gap is not optional in either direction

Treated lumber is sold wet and shrinks. Composite expands with heat. Gap too tight on composite and it buckles in July; gap too wide on wet treated lumber and by autumn you have gaps that swallow a phone.

Screws

1,974 — two at every board-joist crossing, across 21 joists. One screw per crossing lets the board cup and lift at the corner, and that is the single most common reason a deck looks tired after two summers.

Read the end grain

Lay boards bark-side up. A board cups away from its bark side, so bark-up sheds water off the crown rather than holding it in a trough.

Butt joints

Where the run exceeds a standard board length, stagger the joints so no two adjacent rows meet over the same joist — and double the joist under every joint. A butt joint on a single joist gives each board about ¾ inch of bearing, which is not enough for either board.

Notes

  • **Nominal width is not actual width.** A "5/4 ×" board measures 5.5″ across. With a 0.1875″ gap the repeat is 5.688″, which is what decides the row count — 47 rows here. Working from the nominal size undercounts by close to a tenth.
  • Sold dry, so it gaps wider than treated lumber. The gap is not optional in either direction: too tight on composite and it buckles in July; too wide on wet treated lumber and you get gaps you can drop a phone through by autumn.
  • Straight layout, 5% waste — boards run perpendicular to the joists — least waste. This is the least wasteful way to lay a deck, and the fastest.
  • A 20 ft board covers the 20 ft run in one piece. Worth paying for: an unbroken board is stronger, drains better and looks like a deck rather than a repair.
  • Fasten with two screws at every board-joist crossing — 1,974 screws here. One screw lets the board cup and lift at the corner, and it is the single most common reason a deck looks tired after two summers.
  • Lay the boards bark-side up if you can read the end grain. A board cups away from the bark side, so bark-up sheds water off the crown instead of holding it in a trough.

Nearby sizes