JoistLedgerSpans, joists and footings straight from the code tables.

Decking for a 24 × 12 ft deck in 5/4 × 6 treated, diagonal layout

5/4 × 6 pressure-treated boards
60× 12 ft
52 rows across 24 ft — 718 linear ft including 15% waste
Plan — boards across the joists24 ft12 ft52rows5.625″ repeatactual width + gap60 boards · 728 screws
Boards to buy60× 12 ft
Linear feet624 ft plus 15% waste718ft
Rows of decking24 ft ÷ 5.625″ repeat52rows
Board repeat5.5″ actual width + 0.125″ gap — not the nominal size5.625in
Deck area24 × 12 ft288ft²
Joists crossedat 24″ o.c. over 12 ft7joists
Deck screwstwo per board-joist crossing — about 3 boxes of 350728screws
Layoutat 45°, every board is cut at both endsdiagonal
Butt joints12 ft boards cover the 12 ft run in one pieceNone needed
Deck width
24 ft
Deck length
12 ft
Board
5/4 × 6 treated
Layout
diagonal
Joist spacing
24 in o.c.

Nominal width is not actual width

This is where board counts go wrong. A 5/4 × 6 treated board measures its real width, and with the gap it needs the repeat is 5.625″ — which is what actually decides the row count.

24 ft of deck at that repeat is 52 rows, and 60 boards once 15% waste for the diagonal layout is added.

Working from the nominal size undercounts by close to a tenth.

The gap is not optional in either direction

Treated lumber is sold wet and shrinks. Composite expands with heat. Gap too tight on composite and it buckles in July; gap too wide on wet treated lumber and by autumn you have gaps that swallow a phone.

Screws

728 — two at every board-joist crossing, across 7 joists. One screw per crossing lets the board cup and lift at the corner, and that is the single most common reason a deck looks tired after two summers.

Read the end grain

Lay boards bark-side up. A board cups away from its bark side, so bark-up sheds water off the crown rather than holding it in a trough.

Butt joints

Where the run exceeds a standard board length, stagger the joints so no two adjacent rows meet over the same joist — and double the joist under every joint. A butt joint on a single joist gives each board about ¾ inch of bearing, which is not enough for either board.

Notes

  • **Nominal width is not actual width.** A "5/4 ×" board measures 5.5″ across. With a 0.125″ gap the repeat is 5.625″, which is what decides the row count — 52 rows here. Working from the nominal size undercounts by close to a tenth.
  • Sold wet — it shrinks, so gap it tight at about ⅛″. The gap is not optional in either direction: too tight on composite and it buckles in July; too wide on wet treated lumber and you get gaps you can drop a phone through by autumn.
  • Diagonal layout, 15% waste — at 45°, every board is cut at both ends. Order the full allowance in one go; diagonal offcuts rarely fit anywhere else on the deck.
  • A 12 ft board covers the 12 ft run in one piece. Worth paying for: an unbroken board is stronger, drains better and looks like a deck rather than a repair.
  • Fasten with two screws at every board-joist crossing — 728 screws here. One screw lets the board cup and lift at the corner, and it is the single most common reason a deck looks tired after two summers.
  • Lay the boards bark-side up if you can read the end grain. A board cups away from the bark side, so bark-up sheds water off the crown instead of holding it in a trough.

Nearby sizes